ESE lightning Protection Model-95

Earthway Technologies LLP is a leading manufacturer of ESE (Advanced Early Streamer Emission) lightning protection system. It protects against lightning strikes, which can cause the generation of fault currents with the potential to damage electrical equipment and pose risks to human life. Lightning strikes can damage electrical systems and pose risks to human life.

Category:

Working Principle of ESE Lightning Protection System Model - 95

Our ESE (early streamer emission) Lightning Protection System product works with the electric field intensity of the atmosphere. It transmits the electric currents formed in the charged.

The electric atmosphere conditions the interior and ensures that the ion generators in the interior are charged with these electrical currents.

The ion garroters make the atmosphere more conductive by ionizing with surroundings with rapid charge and discharges under this condition, in this way, it makes the lightning discharge that may come on it and transmit it to the ground safely.


During lightning activity, electrical charges inside the thunderstone cloud and the deconcentrating of negative charge at the bottom of the cloud create a giant electric field between the cloud and the ground (Earthing).

The electric field value is calculated depending on the thunderstorm clouds' charge concentration values ranging from 5kV/m to 30kV/m.

Due to this giant electric field, an opposite charge to this cloud concentration will be developed on the earth's surface by the energy effect.

This energy generates a thunderstone cloud Hot cooling any prominent object will get attracted towards the downward leader from the cloud concentration.

In such conditions, air becomes conductive resulting in electrical discharges from such clouds.

The electric field is constant on a flat surface but will be more intense near sharp ports, edges and elevated structures such as trees, buildings, hospitals, Solar plants, Substations, tele towers etc.

For example, on the top of a sharp rod, the E field reaches 300 times more than on a flat surface. The concept of an ESE is to trigger an upward streamer earlier than a conventional rod, by controlling the emission of the streamer.

Why Earthway's Choose Lightning Protection System?

The protection area of Earthway Technologies ESE Lightning Protection System is much wider than a conventional rod, and the electronics circuit is that of Earthway Technologies LLP is able to detect when the lightning is approaching the ground and at this precise moment, it triggers a spark at the tip of the terminal thus involving the emission of an upward streamer which will intercept the lightning.

An upward streamer can develop only if its intensity is sufficient. When lightning is going to occur the intensity of the field becomes about 100 times higher than usual and reaches values Ground (Earthing) 10kV/m this source of energy is reliable and independent from the rain, the sun or the wind.

Earthway Technologies' ESE Lightning Protection System Air terminal uses the ambient electric field as the soured energy.


Installation & Protection levels :

ESE LIGHTNING PROTECTION SYSTEM

Level Of Protection

1 (r= 20 m)

2 (r= 30 m)

 3 (r=45 m)

4 (r= 60m)

Type

ETLPS ESE 45

ETLPS ESE 65 ETLPS ESE 95 ETLPS ESE 45 ETLPS ESE 65 ETLPS ESE 95 ETLPS ESE 45 ETLPS ESE 65 ETLPS ESE 95 ETLPS ESE 45 ETLPS ESE 65 ETLPS ESE 95

h(m)

Radius Of Protection  Rp(m)

2

19 25 31 22 28 35 25 32 39 28 36

48

3

29 38 47 33 42 52 38 48 58 43 57 64

4

38 51 63 44 57 69 51 65 78 57 72

85

5

48 63 79 55 74 86 63 81 97 71 89

107

6

48 63 79 55 74 87 64 81 97 72 90

107

8

49 64 79 56 72 87 65 82 98 73 91

108

10

49 65 79 57 72 88 66 83 99 75 92 109

15

50 65 80 58 73 89 69 85 101 78 95

111

20

50 65 80 59 74 89 71 86 102 81 97

113

45

43 65 76 58 75 89 75 90 105 89 104

119

50

40 65 74 57 75 88 75 90 105 89 104

120

55

36 65 72 55 75 86 74 90 105 90 105

120

60

30 65 69 52 75 85 73 90 104 90 105

120

NOTE - The optimized radius is reached when placing the ESE lightning conductor at 5m & 8m above the highest point the structure to protection. A minimum of 2m is a must.

Reviews

There are no reviews yet.

Be the first to review “ESE lightning Protection Model-95”

Your email address will not be published. Required fields are marked *