Earthway Technologies LLP is a leading ESE (Advanced Early Streamer Emission) lightning protection system manufacturer.

It protects against lightning strikes, which can cause the generation of fault currents with the potential to damage electrical equipment and pose risks to human life. Lightning strikes can damage electrical systems and pose risks to human life.

Our Benefit

Working Principle of ESE Lightning Protection System Model - 65

01

Atmospheric Electric Field

The system works by responding to the electric field intensity of the atmosphere, which drives electric currents in the charged environment.
02

Ion Generators Charging

The electric atmosphere conditions the interior of the system, ensuring the ion generators charge with these electrical currents.
03

Ionization for Conductivity

The ion generators ionize the surrounding atmosphere, enhancing conductivity and promoting rapid charge and discharge cycles to safely guide lightning strikes to the ground.
04

Thunderstorm Electric Field

During a lightning storm, the electrical charges in the cloud and the concentration of negative charges create a large electric field between the cloud and the earth's surface.
05

Electric Field Calculation

The electric field value, which ranges from 5kV/m to 30kV/m, is based on the concentration of charge in the thunderstorm clouds.
06

ESE Concept for Early Emission

The ESE system triggers an upward streamer earlier than traditional rods, effectively controlling the emission of the streamer for enhanced lightning protection.
Services

Application

Engines prime movers and exhaust gas turbochargers.

DALL·E 2024-12-14 09.18.30 - An industrial and residential setup showing the application of copper earthing electrodes for high_low voltage use. The image includes a power substat
Prevents electric arcs and fire hazards.
DALL·E 2024-12-14 09.20.47 - A visually detailed image depicting copper earthing electrodes in both domestic and industrial settings. On one side, a modern house with visible grou
Supports power, telecom, and more
Gemini_Generated_Image_nd7qxnd7qxnd7qxn
Ideal for power and communication setups.
Gemini_Generated_Image_dq6tu0dq6tu0dq6t
Reduces static charges and stray currents.
Gemini_Generated_Image_injjm2injjm2injj
Ensures effective neutral grounding performance

Industries

Petrochemical, CNG, and Nuclear Facilities
Data Centre, Telecom and Broadcasters
Process control and automation Industries
Hospital, Government, Military, and defence

Get An Enquiry

Technical Specification

Specification Details
Material 99.9% Pure electrolytic grade copper
Available Ball dia 45mm / 65mm
Available Length 2ft
Spike Material Copper
No of Spike 5 Spike
Insulated Base Plate HDP Material (100x100x10mm)

Some Key Points About lightning protection system

01

Purpose

The main goal is to prevent lightning strikes from causing damage to structures, electrical systems, and human life by directing the electrical charge safely into the ground.
02

Importance of Proper Grounding

A properly designed grounding system ensures that the lightning energy is safely discharged into the earth, preventing electrical damage and fires.
03

Surge Protection

In addition to the physical LPS, surge protection devices are installed to protect electrical circuits and sensitive electronic equipment from voltage spikes caused by lightning strikes.
04

Maintenance

Regular inspection and maintenance of the LPS are critical to ensure its functionality. Components should be checked for corrosion, damage, and proper connection to the grounding system.
05

Effectiveness

An LPS significantly reduces the risk of lightning-related damage, but it does not guarantee complete protection. Its effectiveness depends on proper design, installation, and maintenance.
06

Risk Assessment

A risk assessment is often performed to determine the necessity and extent of lightning protection based on the structure's location, height, and usage, along with environmental factors like lightning frequency in the area.